Home > Read Error > Rawread Error Code 11

Rawread Error Code 11

Contents

Of course they zap all the smart attributes first. Technical Committee T13. share|improve this answer answered Feb 12 '11 at 10:56 harrymc 191k7166408 1 The Current and Worst values for temperature can never be read directly from SMART data. The Committee chose IntelliSafe's approach, as it provided more flexibility. http://peakappcare.com/read-error/read-error-code.php

August 2010. The factory default is eight (8) seconds, which is a very poor choice for use with Linux. Zatick 2013-09-17 23:38:27 UTC #8 It might be easier if you give a bit of information about what software/tools you are already running. This test usually takes several hours, depending on the read/write speed of the drive and its size.

Raw Read Error Rate Fix

While primarily used as a metric of the life expectancy of the drive, this number also affects performance. [See standard ACS-3 for more information] 06 0x06 Read Channel Margin Margin of That SFF standard described a communication protocol for an ATA host to use and control monitoring and analysis in a hard disk drive, but did not specify any particular metrics or PeterB Community Developer Hero Member Posts: 2440 Re: Raw Read Error Rate. « Reply #13 on: August 29, 2015, 08:56:30 AM » HAd a short spell of this happening again, this Status code = 04 (Unknown failed test element), Failure Checkpoint = 96 (Unknown Test) SMART self-test did not complete on drive 4!

It provides only two values: "threshold not exceeded" and "threshold exceeded". C Power Cycle Count 100 OK 100 100 0 N.A. Such a failure may be due to numerous factors, such as damage to a servo, or thermal widening of the hard disk. How To Fix Raw Read Error Rate Samsung When Drive Health software reports a "Nearest T.E.C.", it should be regarded as a "Failure date".

Remember to disable spin down if running the long test, as it can result in a false failure. Here's the fix.". although i could view them with Vista default picture viewer: im assuming those pictures are unrecoverable. OCZ tool shows only 114 total ECC and RAISE errors.

Acronis Knowledge Base. Current Pending Sector Count Hungary. 2007. propergol 2013-09-19 08:56:43 UTC #12 But  I realy wonder why I am doing this test... there are 46 files (all pictures) in that log.

What Is Raw Read Error Rate

I need to sleep now, but I'll check it in the morning, if someone else hasn't helped first. Thanks for your information, Ricky Comment Post Cancel David (PassMark) Administrator Join Date: Jan 2003 Posts: 5905 #14 06-21-2007, 07:25 AM What message are you referring to? Raw Read Error Rate Fix Thanks again, Great community! #4 (permalink) July 1, 2012, 08:23 PM frontier204 Hall Of Fame Join Date: Nov 2008 Location: Ottawa, ON Posts: 1,305 My System Specs You Raw Read Error Rate 1 Zatick 2013-09-17 22:28:35 UTC #6 It seems unlikely that a drive will be replaced based on raw read error rate.

C8 Write Error Count 0 OK 100 253 0 N.A. No Conveyance Self-test supported. bjp999 Global Moderator Hero Member Posts: 5757 ASRock E3C224-4L/A+, SM C2SEE/B, Asus P5B VM DO/C Re: Raw Read Error Rate. « Reply #14 on: August 29, 2015, 10:12:11 AM » Whatever Attributes are further discussed below.[14] Drives with SMART may optionally maintain a number of 'logs'. Raw Read Error Rate Ssd

Haha, this'll be its final test =P Thaks again, i'll keep you updated. Could you explained the cable fault test and whether it could be solved by replacing the usb (Type A to Mini Type B) cable? reports will function correctly in a given system. http://peakappcare.com/read-error/read-error-for-default-code-sdf.php Why mine is 1?

utilities will report a negative number for the raw value since in reality it has 48 bits rather than 32. 243 0xF3 Total LBAs Written Expanded The upper 5 bytes of Crystaldiskinfo The lower 7 byte value is located at attribute 0xF1.[62] 244 0xF4 Total LBAs Read Expanded The upper 5 bytes of the 12-byte total number of LBAs read from the device. Many of then stick at 0 and others have huge numbers that, as RobJ mentioned, as not interpretable without technical docs that drive manufacturers do not publish.

The second time, just the other day, I can close to losing windows but managed to save it.

The unRAID Main page drive error counts could also be interface issues, problems with the cabling or controller, etc. raw read error rate : keeps growing, its now 18323 and today, a good news :  2  Pending Sector Count... I mean is there smoke pouring out of the drive or something that you are basing your bad feelings on? Reallocated Sector Count However, this is the first time I have seen a non-zero value for this attribute, on any drive.What is the advice/experience of unRAID users - should I be concerned?

This is a serious shortcoming, for if such a drive contains marginal sectors that consistently fail only after some time has passed following a successful write operation, then the drive will Now some drives require repair, but a drive that has been disassembled by human hands to replace parts is not necessarily factory fresh either.All in all, I'd say refurbs are a I'm not sure if this ok or not, or should I ask for repalcement from the supplier or not... If Selective self-test is pending on power-up, resume after 0 minute delay.

Would WD be likely to swap this drive under warranty?Edit to add:The main tab on the unRAID webcui is reporting:Code: [Select]Disk 2 WDC_WD30EFRX-68EUZN0_WD-WMC4N2597206 - 3 TB (sdc) For example, I don't believe that you had a temperature peak of 129 degrees celcius. Source forge. ^ a b c d S.M.A.R.T. I'd rather know if the problem is really the drive before returning a disk with near perfect attributes.

But if you take that and convert it into the proper formatted value (starting at 100, counting down to 0, with a value 6 or below being failed), then it's at Ask ! S.M.A.R.T. Why the description says that disk had 89.970.873 read errors?

Logged myMain authorTroubleshootingBest of the Forums My New Rig (and here) myMain Instructions and here / Monitoring PreclearsNew Users Start HereWhat is Parity?Best Practices: Replace Parity / Replace Flash / Migrate Hewlett-Packard.